Data Models
autostorage uses SQLModel/SQLAlchemy to define a relational schema for computational chemistry workflow data. The models form a graph structure where molecular geometries, calculations, stationary points, and chemical identities are linked through explicit relationship tables.
Model Overview
The schema is organized into five functional groups:
Link Tables
Association tables implementing many-to-many relationships between entities.
| Model | Description |
|---|---|
| CalculationGeometryLink | Associates geometries with calculations, tracking whether each geometry is an input or output |
| GeometryTrajectoryLink | Links geometries to trajectories with position indices and, optionally, the physical value along each dimension (values) |
| CalculationTrajectoryLink | Associates trajectories with calculations as inputs or outputs |
| StageStationaryLink | Connects stationary points to reaction stages |
| StepValidationLink | Links validation calculations to reaction steps |
| IdentityStationaryLink | Associates chemical identities with stationary points; its identity_cache holds data that makes generating identities cheaper |
Core Data Models
The fundamental entities representing molecular structures, calculations, and their results.
| Model | Description |
|---|---|
| GeometryRow | Molecular geometry with atomic symbols, coordinates, charge, and spin; extends autogeom.Geometry |
| TrajectoryRow | Ordered sequence of geometries from a dynamic calculation; view(axis, at) animates the geometries along one dimension, and values_along(axis, at) gives their physical values |
| TrajectoryAxisRow | The physical coordinate (distance, angle, dihedral, or other) that one dimension of a trajectory runs along, such as a scanned dihedral |
| ModelRow | Calculation model specification (program, method, basis set, keywords) |
| CalculationRow | Quantum chemistry calculation with provenance metadata |
| PropertyKindRow | A kind of property (energy, gradient, hessian, …), mirroring PropertyKindRegistry by name |
| PropertyValueRow | A property value for a geometry/calculation pair, validated against its kind’s expected shape |
| ValidationRow | Validation result (e.g., IRC) for a reaction step |
Stationary Points
Models representing critical points on potential energy surfaces.
| Model | Description |
|---|---|
| StationaryPointRow | A stationary point with Hessian index and validation status |
Reaction Network
Models defining elementary reaction steps and their constituent chemical states.
| Model | Description |
|---|---|
| StageRow | A chemical state in a reaction (reactant, product, or transition state) |
| StepRow | An elementary reaction step connecting two stages via a transition state (or barrierless) |
Chemical Identities
Models for chemical identification and classification.
| Model | Description |
|---|---|
| IdentityAlgorithmRow | An identity algorithm (name, kind, parent), mirroring an IdentityAlgorithm |
| IdentityRow | A chemical identifier value (InChI, SMILES, Hill formula, …) generated by an algorithm; attached to stationary points automatically |
Scans and Other Trajectories
A trajectory’s geometries are placed on a grid by their integer index. To record what a dimension means physically, such as the dihedral angle of a relaxed scan, give the trajectory a TrajectoryAxisRow for that dimension:
from autostorage import AxisKind, GeometryTrajectoryLink, TrajectoryAxisRow, TrajectoryRow
scan = TrajectoryRow()
scan.axes.append(
TrajectoryAxisRow(
axis=0, kind=AxisKind.DIHEDRAL, keys=[0, 1, 2, 3], label="H-O-O-H torsion"
)
)
for i, geo in enumerate(scan_geometries):
scan.geometry_links.append(GeometryTrajectoryLink(geometry=geo, index=[i]))
session.add(scan)
session.commit()
scan.values_along(0) # dihedrals in degrees, in index order
scan.values_along(0, units="radian")On flush, each link’s values (one per dimension, aligned with index) are filled in:
- Missing values of distance, angle, and dihedral axes are measured from the geometry with autogeom. Distances default to Angstrom and angles to degrees; set units on the axis to store them in other units. Measured dihedrals lie between -180° and 180°.
- Given values are kept, so you can store a scan’s nominal (constrained) values instead. A
pint.Quantityis converted to the axis’s units. - AxisKind.OTHER axes (e.g. an IRC arc length) are never measured, so their values must be given.
- Adding an axis to a stored trajectory fills in the values of its existing geometries.
Design Principles
- autogeom integration: GeometryRow extends
autogeom.Geometrydirectly rather than wrapping it, delegating validation and format conversions to autogeom - Identities from a registry: identities are generated by the algorithms in IdentityAlgorithmRegistry (see Identities)
- Registries mirrored by name: IdentityAlgorithmRow and PropertyKindRow rows are seeded from their in-memory registries when a Database is opened, and looked up by name
- Explicit relationships: Many-to-many relationships use dedicated link tables rather than implicit joins
- Cascading deletes: deleting a row deletes its link rows and the data that depends on it: a model’s calculations, a geometry’s or calculation’s property values and stationary points, and a calculation’s validations. Geometries, stages, steps, and identities are kept
- Provenance tracking: Calculations record both input and output provenance metadata
- Native units: each property kind declares its native units (
energyin Hartree,gradientin Hartree/Bohr,hessianin Hartree/Bohr²). Values are always stored in them: apint.Quantity(e.g.autogeom.ureg.Quantity(-1.2, "kcal/mol")) is converted on flush, and a value without units is assumed to be in the native units already. molar units such as kcal/mol are converted with Avogadro’s constant.PropertyKind.from_native(value, "kcal/mol")converts a stored value back out, and PropertyKind.quantity attaches the native units to it - Validated stationary points: on flush, a stationary point is marked
is_validatedif every Hessian of its geometry hasordernegative eigenvalues after translations and rotations are projected out (autogeom.vibrational_analysisandautogeom.stationary_point_order). Otherwise,is_validatedis reset toFalseand a StationaryOrderWarning is issued. This check runs again when the point or one of its Hessians is added, changed, or deleted. Pseudo stationary points are skipped - Compressed storage: NumPy arrays (coordinates and property values) are stored as zlib-compressed binary data via CompressedArrayTypeDecorator; property values are stored as float64, except Hessians (float32). Identity caches are stored as zlib-compressed JSON via CompressedJSONTypeDecorator
- Graph structure: The schema forms a directed graph where calculations consume and produce geometries/trajectories, geometries carry results, stationary points reference geometries, and reaction steps connect stages